TKWL-1700 Series Capacitive Level Gauge

The TKWL-1700 Series Capacitive Level Gauge is a level transmitter for measuring liquids, oils and solids. With no moving parts, it offers high reliability, high sensitivity, good linearity and stable long-term operation.

It is not affected by water vapor, dust or condensation, and is widely used in petroleum, chemical, metallurgy, power, paper and pharmaceutical applications.

When installed in a vessel, the capacitive level gauge forms a capacitor. The metal probe acts as one electrode, and the vessel wall or reference electrode acts as the other. As the level rises, the dielectric material between the electrodes changes, causing capacitance change. The RF circuit detects this capacitance change and converts it into a linear current output.

  • Simple structure with no moving or elastic parts.
  • High reliability and low maintenance requirement.
  • Measurement values are not affected by liquid temperature, vessel shape or pressure.
  • Suitable for corrosive liquids such as acids and alkalis.
  • Overcurrent, overvoltage and power polarity protection.
  • Can measure conductive media.
Item TKWL-1700 TKWL-1701
Measurement range 0-30 m 0-6 m
Capacitance range 0.1 pF to 2000 pF 0.1 pF to 2000 pF
Accuracy Class 0.5 Class 0.5
Operating pressure -0.1 to 2 MPa -0.1 to 2 MPa
Operating temperature -50 to 200°C -50 to 200°C
Ambient temperature -40 to 85°C -40 to 85°C
Output signal 4-20 mA / HART 4-20 mA / HART
Power supply 24 VDC 24 VDC
Process connection Thread, flange or bracket Thread, flange or bracket
  • Sensor type: cable type or rod type.
  • Installation method: M20×1.5 thread, G1 thread, DN50 flange or other.
  • Output signal: 4-20 mA or 4-20 mA + HART.
  • Electrical interface: M20×1.5, 1/2NPT or special customization.
  • Probe material: 304+PTFE, 316L+PTFE or special customization.
  • Probe or cable length is specified in millimeters.
  • Measurement range and sensor type.
  • Medium type and whether it is corrosive or conductive.
  • Probe material and process connection.
  • Output signal and electrical interface.
  • Operating pressure, temperature and probe length.
  • TKWL-1900 series RF admittance level switch.
  • TKWL-130 series magnetostrictive level gauge.