TKWL-1900 Series RF Admittance Level Switch
Product Overview
Section titled “Product Overview”The TKWL-1900 Series RF Admittance Level Switch is a level control technology developed from capacitive measurement. It is designed to resist material buildup and provide reliable, accurate level switching in a wide range of applications.
RF admittance measurement uses high-frequency radio waves to measure the admittance value of the medium, enabling level detection for liquids and solids.
Product Principle
Section titled “Product Principle”The switch applies radio frequency to the probe and continuously analyzes the surrounding environment. Since the dielectric constant and conductivity of the medium differ from air, the small capacitance change when the probe contacts the medium is detected and converted into a switch output. Its anti-adhesion circuit responds only to capacitance changes caused by actual level change.
Product Features
Section titled “Product Features”- Fully sealed integrated installation structure.
- Digital integrated circuit with no mechanical moving parts.
- Low temperature drift and reduced influence from temperature and humidity.
- Anti-adhesion circuit to avoid false signals caused by material buildup.
- Suitable for high temperature, high pressure, heavy dust and high viscosity applications.
Technical Specifications
Section titled “Technical Specifications”| Item | Specification |
|---|---|
| Model | TKWL-1900 |
| Power supply | 24 VDC / 220 VAC |
| Output mode | SPDT / DPDT relay |
| Ambient temperature | -20 to 80°C |
| Medium temperature | -40 to 200°C / -40 to 600°C |
| Operating pressure | <2 MPa |
| Insulation sheath | PPS, PTFE or ceramic |
| Sensitivity | 0.5 pF to 750 pF |
| Process connection | Threaded or flanged |
Model Selection
Section titled “Model Selection”- Electrical entry: M20×1.5, 1/2NPT or customized.
- Power supply: DC24 V or AC220 V.
- Installation type: integral or separate.
- Process temperature: -40 to 200°C or -40 to 600°C.
- Probe material: 304+PPS, 304+PTFE, 316L+PTFE, 304+ceramic, 316L+ceramic or customized.
- Process connection: NPT3/4 thread, DN25 flange, DN50 flange or other.
- Probe or cable length is specified in millimeters.
Information Required for Inquiry
Section titled “Information Required for Inquiry”- Medium type and whether buildup, dust or high viscosity is present.
- Process temperature and operating pressure.
- Power supply and relay output requirement.
- Probe material, process connection and insertion length.
- Integral or separate installation requirement.
Related Products
Section titled “Related Products”- TKWL-1700 series capacitive level gauge.
- TKWL-2100 series fork level switch.
Product Downloads
Section titled “Product Downloads”View this product PDF catalogue online, or return to the Level Meter downloads page for related documents.