Armored thermocouples are normally used together with display instruments, recording instruments and electronic computers. They directly measure the temperatures of liquid, steam, gas media and solid surfaces in production processes, within a measurement range of 0 to 1300°C. The thermocouple is made from two different conductor materials. A temperature difference between the measuring end and reference end generates a thermoelectric potential, which the instrument indicates as the corresponding temperature.

- Temperature measurement of liquid, steam and gas media in production processes.
- Solid surface temperature measurement.
- Applications requiring temperature measurement and recording together with display instruments, recording instruments or electronic computers.
- Short thermal response time to reduce dynamic errors.
- Bendable mounting for use and adaptation to site routing.
- Large measurement range, with a maximum of 1300°C.
- High mechanical strength and good pressure resistance.
- Junction box protection level available in IP65 and IP66.
- Fixed thread.
- Adjustable ferrule thread.
- Fixed flange.
- Adjustable ferrule flange.
- A contact block additional device (M) or hoop additional device (G) is available. For contact block or hoop selection, provide the pipe or furnace-wall diameter R.
| Item |
Standard |
| International standard |
IEC60584 |
| National standards |
GB/T18404, GB/T30429 |
| Model |
Graduation |
Class I temperature range and permissible deviation |
Class II temperature range and permissible deviation |
| WRNK |
K |
-40 to 375°C: ±1.5°C; 375 to 1000°C: ±0.004|t| |
-40 to 333°C: ±2.5°C; 333 to 1200°C: ±0.0075|t| |
| WRMK |
N |
-40 to 375°C: ±1.5°C; 375 to 1000°C: ±0.004|t| |
-40 to 333°C: ±2.5°C; 333 to 1200°C: ±0.0075|t| |
| WREK |
E |
-40 to 375°C: ±1.5°C; 375 to 800°C: ±0.004|t| |
-40 to 333°C: ±2.5°C; 333 to 900°C: ±0.0075|t| |
| WRFK |
J |
-40 to 375°C: ±1.5°C; 375 to 750°C: ±0.004|t| |
-40 to 333°C: ±2.5°C; 333 to 750°C: ±0.0075|t| |
| WRCK |
T |
-40 to 125°C: ±0.5°C; 125 to 350°C: ±0.004|t| |
-40 to 133°C: ±1.0°C; 133 to 350°C: ±0.0075|t| |
| WRPK |
S |
0 to 1100°C: ±1.0°C; 1100 to 1600°C: ±[1+0.003(t-1100)] |
0 to 600°C: ±1.5°C; 600 to 1600°C: ±0.0025|t| |
| WRQK |
R |
0 to 1100°C: ±1.0°C; 1100 to 1600°C: ±[1+0.003(t-1100)] |
0 to 600°C: ±1.5°C; 600 to 1600°C: ±0.0025|t| |
| WRRK |
B |
/ |
600 to 1700°C: ±0.0025|t| |
| Graduation |
Sleeve material |
Sleeve outside diameter |
Maximum recommended service temperature |
| K, N |
0Cr18Ni9Ti |
Φ0.25 mm |
250°C |
| K, N |
0Cr18Ni9Ti |
Φ0.5, Φ1.0 mm |
400°C |
| K, N |
0Cr18Ni9Ti |
Φ1.5, Φ2.0 mm |
600°C |
| K, N |
0Cr18Ni9Ti |
Φ3, Φ4, Φ4.5, Φ5, Φ6, Φ8 mm |
800°C |
| K, N |
GH3030, Inconel600 |
Φ0.25 mm |
300°C |
| K, N |
GH3030, Inconel600 |
Φ0.5, Φ1.0 mm |
500°C |
| K, N |
GH3030, Inconel600 |
Φ1.5, Φ2, Φ3 mm |
800°C |
| K, N |
GH3030, Inconel600 |
Φ4, Φ4.5, Φ5 mm |
900°C |
| K, N |
GH3030, Inconel600 |
Φ6, Φ8 mm |
1000°C |
| E |
0Cr18Ni9Ti |
Φ0.5, Φ1.0 mm |
400°C |
| E |
0Cr18Ni9Ti |
Φ1.5, Φ2 mm |
500°C |
| E |
0Cr18Ni9Ti |
Φ3, Φ4, Φ4.5 mm |
600°C |
| E |
0Cr18Ni9Ti |
Φ5, Φ6, Φ8 mm |
700°C |
| J |
0Cr18Ni9Ti |
Φ0.5, Φ1.0 mm |
300°C |
| J |
0Cr18Ni9Ti |
Φ1.5, Φ2 mm |
400°C |
| J |
0Cr18Ni9Ti |
Φ3, Φ4, Φ4.5 mm |
500°C |
| J |
0Cr18Ni9Ti |
Φ5, Φ6, Φ8 mm |
600°C |
| T |
0Cr18Ni9Ti |
Φ0.5, Φ1.0 mm |
200°C |
| T |
0Cr18Ni9Ti |
Φ1.5, Φ2, Φ3, Φ4, Φ4.5 mm |
250°C |
| T |
0Cr18Ni9Ti |
Φ5, Φ6, Φ8 mm |
300°C |
| S, R |
GH3039 |
Φ2, Φ3, Φ4, Φ4.5 mm |
1000°C |
| S, R |
GH3039 |
Φ5, Φ6, Φ8 mm |
1100°C |
| B |
GH3039 |
Φ2, Φ3, Φ4, Φ4.5, Φ5, Φ6, Φ8 mm |
1200°C |
Sleeve material can be specially customized according to customer requirements.
| Sleeve outside diameter |
Φ0.5 mm |
Φ1 mm |
Φ1.5 mm |
Φ2 mm |
Φ3 mm |
Φ4 mm |
Φ4.5 mm |
Φ5 mm |
Φ6 mm |
Φ8 mm |
| Exposed end type |
/ |
0.1 s |
0.2 s |
0.3 s |
0.4 s |
0.5 s |
0.6 s |
0.7 s |
0.8 s |
1.0 s |
| Shell type |
0.2 s |
0.2 s |
0.3 s |
0.4 s |
0.6 s |
0.8 s |
1.0 s |
1.2 s |
2.0 s |
4.0 s |
| Insulation type |
0.4 s |
0.6 s |
0.8 s |
1.0 s |
2.0 s |
2.5 s |
3.0 s |
4.0 s |
6.0 s |
8.0 s |
| Item |
Parameter |
| Ambient temperature |
20±15°C |
| Relative humidity |
Not more than 80% |
| Test voltage |
DC 500±50 V |
| Insulation resistance between electrode and outer sleeve |
Not less than 1000 MΩ |
| Insulation resistance of 1 m sample |
1000 MΩ |
| Insulation resistance of 10 m sample |
100 MΩ |
- Measuring-end form: exposed end type, shell type and insulation type.
- Junction box: waterproof type, round plug-in type, plug-in type, flat plug-in type, handle type and compensating conductor type.
- Thermocouple quantity: single or double.
- Sleeve outside diameter: Φ2, Φ3, Φ4, Φ5, Φ6 and Φ8 mm.
- Sleeve material can be specially customized according to customer requirements.
- WRNK-010
- WRNK-185
- WRNK-235
- WRNK-275
- WRNK-295
- WRNK-335
- WRNK-365
- WRNK-435
- WRNK-535
- Required model, graduation and accuracy class.
- Installation and fixing form, and whether a contact block or hoop additional device is required.
- Protective sleeve material, outside diameter, overall length L and insertion depth I.
- Measured medium, operating temperature range and site pressure.
- For a contact block or hoop additional device, provide the pipe or furnace-wall diameter R.
- Display instruments, recording instruments and electronic computers: armored thermocouples are normally used with these products.