Product Overview
Section titled “Product Overview”The TK-3051-DPG Downhole Pressure Gauge Transmitter provides continuous downhole pressure and temperature measurement. The pressure signal is amplified, converted by a 24-bit A/D converter and processed by a microprocessor before being transmitted through a dedicated logging cable to the surface modem and control system. Pressure and temperature can be acquired downhole, with surface calibration and communication configuration available.
Applications
Section titled “Applications”- Coalbed methane wells, oil and gas wells and deepwater wells.
- Conventional oil and gas wells, shale gas wells and directional wells.
- Ultra-deep coalbed methane wells, horizontal wells and high-temperature/high-pressure wells.
- Logging systems requiring simultaneous downhole pressure and temperature transmission.
Product Features
Section titled “Product Features”- Pressure and temperature measurement: Acquires pressure and temperature together, with temperature available for compensation.
- High-resolution conversion: Uses a 24-bit A/D converter and high-accuracy pressure measurement circuit.
- Long-distance communication: Supports MODBUS-RTU and RS485 communication through a single-core logging cable.
- Downhole sealing: Downhole sealing pressure is not less than 60 MPa; wellhead sealing pressure is 5 MPa.
- Maintenance and calibration: Supports surface zero calibration, atmospheric pressure calibration, laboratory calibration and remote configuration.
- Cable capability: Cable outer diameter is not more than 8 mm, with wear-resistant, tensile and gas-barrier construction.
Main Technical Parameters
Section titled “Main Technical Parameters”| Item | Specification |
|---|---|
| Pressure range | 0.6-60 MPa |
| Pressure accuracy | 0.05% F.S. |
| Pressure resolution | 0.05 kPa |
| Temperature range | -40 to 150 °C |
| Temperature accuracy | 0.25 °C |
| Temperature resolution | 0.1 °C |
| Pressure/temperature refresh cycle | 1 s |
| Communication output | MODBUS-RTU and RS485 |
| Input power | 24 VDC, 18-30 VDC |
| Surface operating temperature | -25 to 80 °C, with LCD indication available |
| Downhole sealing pressure | Not less than 60 MPa |
| Wellhead sealing pressure | 5 MPa |
| Installation | Fixed downhole base with supporting shock absorption |
Model Parameters
Section titled “Model Parameters”| Model | Pressure range | Temperature range | Applicable well depth | Cable |
|---|---|---|---|---|
| TK-3051-DPG-1 | 0-10 MPa | -4 to 150 °C | 0-1200 m | Single-core logging cable |
| TK-3051-DPG-2 | 0-25 MPa | -40 to 150 °C | 0-2000 m | Single-core steel logging cable |
| TK-3051-DPG-3 | 0-60 MPa | -40 to 150 °C | 0-5000 m | Single-core steel logging cable |
Model Characteristics
Section titled “Model Characteristics”- DPG-1 is intended for coalbed methane wells, oil and gas wells, deepwater wells and horizontal wells.
- DPG-2 is intended for conventional oil and gas wells, shale gas wells and directional wells, with cable-channel redundancy.
- DPG-3 is intended for conventional oil and gas wells, shale gas wells, ultra-deep coalbed methane wells, directional wells and horizontal wells under high-temperature and high-pressure conditions.
Installation and Communication
Section titled “Installation and Communication”- Fixed downhole base installation with supporting shock absorption.
- Simultaneous pressure and temperature transmission through a single-core logging cable.
- Gas-barrier construction inside the cable helps reduce gas entry after cable damage.
- MODBUS-RTU communication, RS485 interface and surface modem connection.
Maintenance and Calibration
Section titled “Maintenance and Calibration”The downhole pressure gauge should be brought to the surface for regular calibration, with a calibration interval of no more than three years. Surface zero calibration, atmospheric pressure calibration, laboratory calibration and remote configuration can be performed according to the field requirements. Laboratory calibration can use the verification software and technical support.
Information Required for Quotation
Section titled “Information Required for Quotation”- Well type, medium and application.
- Maximum pressure, temperature and well depth.
- Required DPG-1, DPG-2 or DPG-3 model.
- Downhole accessories, wellhead accessories and logging cable.
- Communication protocol, RS485 interface and surface control system.
- Downhole sealing, wellhead sealing and calibration requirements.
Related Products
Section titled “Related Products”- Fixed downhole bases and shock-absorption accessories.
- Wellhead sealing assemblies.
- Single-core logging cables and surface modems.
- RS485 communication equipment, verification software and calibration accessories.
Product Downloads
Section titled “Product Downloads”View this product PDF catalogue online, or return to the Pressure Transmitter downloads page for related documents.
View Product PDF View All Pressure Transmitter Downloads